Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: The introduction of portable monitors (point-of-care devices) for the management of patients on oral anticoagulation allows self-testing by the patient at home. Patients who self-test can either adjust their medication according to a pre-determined dose-INR schedule (self-management) or they can call a clinic to be told the appropriate dose adjustment (self-monitoring). Several trials of self-monitoring of oral anticoagulant therapy suggest this may be equal to or better than standard monitoring. OBJECTIVES: To evaluate the effects of self-monitoring or self-management of oral anticoagulant therapy compared to standard monitoring. SEARCH STRATEGY: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2007, Issue 4), MEDLINE, EMBASE and CINAHL (to November 2007). We checked bibliographies and contacted manufacturers and authors of relevant studies. No language restrictions were applied. SELECTION CRITERIA: Outcomes analysed were thromboembolic events, mortality, major haemorrhage, minor haemorrhage, tests in therapeutic range, frequency of testing, and feasibility of self-monitoring and self-management. DATA COLLECTION AND ANALYSIS: The review authors independently extracted data. We used a fixed-effect model with the Mantzel-Haenzel method to calculate the pooled risk ratio (RR) and Peto's method to verify the results for uncommon outcomes. We examined heterogeneity amongst studies with the Chi(2) and I(2) statistics. MAIN RESULTS: We identified 18 randomized trials (4723 participants). Pooled estimates showed significant reductions in both thromboembolic events (RR 0.50, 95% CI 0.36 to 0.69) and all-cause mortality (RR 0.64, 95% CI 0.46 to 0.89). This reduction in mortality remained significant after the removal of low-quality studies (RR 0.65, 95% CI 0.46 to 0.90). Trials of self-management alone showed significant reductions in thromboembolic events (RR 0.47, 95% CI 0.31 to 0.70) and all-cause mortality (RR 0.55, 95% CI 0.36 to 0.84); self-monitoring did not (thrombotic events RR 0.57, 95% CI 0.32 to 1.00; mortality RR 0.84, 95% CI 0.50 to 1.41). Self-monitoring significantly reduced major haemorrhages (RR 0.56, 95% CI 0.35 to 0.91) whilst self-management did not (RR 1.12, 95% CI 0.78 to 1.61). Twelve trials reported improvements in the percentage of mean INR measurements in the therapeutic range. No heterogeneity was identified in any of these comparisons. AUTHORS' CONCLUSIONS: Compared to standard monitoring, patients who self-monitor or self-manage can improve the quality of their oral anticoagulation therapy. The number of thromboembolic events and mortality were decreased without increases in harms. However, self-monitoring or self-management were not feasible for up to half of the patients requiring anticoagulant therapy. Reasons included patient refusal, exclusion by their general practitioner, and inability to complete training.

Type

Journal article

Journal

Cochrane database of systematic reviews (Online)

Publication Date

01/01/2010

Volume

4